ACO-8/8as Automated Cleveland Open Cup Flash Point Tester

ACO-8/8as Automated Cleveland Open Cup Flash Point Tester
(cập nhật 06-02-2015)
Giá bán
Liên hệ
ID Sản phẩm
G-0009844-00008
Cam kết
Hàng mới 100%
Xuất xứ
Bảo hành
Điện thoại
Email
Zalo

ACO-8/8as Automated Cleveland Open Cup Flash Point Tester

Single Action Setting: The flash detector rings and the temperature sensor are permanently mounted on a swing-arm assembly, which allows easy setting of the specimen.

Easy Operation: Select a test mode and enter the expected flash point; while the instrument executes the test, you are free to do other lab work. The tester follows the exact procedures prescribed in the test method, and the completion of the test cycle is signaled by beeps. The test result is brightly shown on the VFD module.

Auto Fire Point Detection: In addition to the flash point, fire point can be determined automatically. The fire point is detected when the double ionization rings detect 5 sec of continuous burning.

Auto Fire Containment: ACO-7 is equipped with a fire containment lid which activates automatically to help extinguish the fire when ACO-7 detects a fire point or specimen is burning heavily.

Modular Design: The tester consists of a computer control unit and a test head unit, allowing remote placing of the test head unit up to 3 meters away. An optional Changeover unit can be purchased to attach the control unit to another type of flash point test head unit (APM-8 or ATG-8). The control unit is designed to control any of the three different flash point test head units, one at a time.

Specifications

Conforming Standards:
ISO 2592, ASTM D92, IP 36, etc.

Measuring Standards:
Ambient to 400 oC

Test Mode:
ASTM D92 Flash + Fire, Special (Fast Search),
User’s Custom

Display:
Fluorescent display tube (VFD Module)

Temperature Sensor:
PT-100 in stainless steel sheath

Flash Detector:
Ionization Ring

Heater:
Nichrome Coil heater: 800W@100V or 800W@220V

Ignition Source:
Gas ignition with automatic lighting

Skimming Mechanism (Asphalt Version Only):
Paddle rotates to skim the surface of the specimen. Skimming start temp and interval are programmable. When not in use, the paddle can be removed.

Cooling Device:
Forced air cooling by sirocco fan

Barometric Correction:
By entering the barometric pressure reading through the control panel, or by an optional barometric pressure sensor

Data Output:
RS-232C 1 channel (for PC or Optional Printer)

Safety Mechanism:
Fire containment lid which activates automatically to help extinguish the fire when the ACO-7 detects a fire point

Automatically shuts off and the problem is reported by buzzer and display, in case:

    1 EFP+30oC or at 400oC is reached
    2 Temperature sensor is found defective
    3 Flash detector is found defective
    4 Thermofuse is blown (Also fire containment lid activates)
    5 Built-in battery is found drained
    6 Arm is not set in place
    7 Control computer crashes (no display)

Dimensions & Weight:
Control unit: 230W x 455D x 110H (mm), 6.0kg
Test unit: 230W x 450D x 275H (mm), 14.0kg
Test unit: 230W x 450D x 345H (mm), 14.5kg (Asphalt Version)

Installation Site:
Ambient temperature: 0 to 40oC
RH: Less than 90%(no condensation)

Utility:
AC100/120V or 220/240V 50/60Hz (set at the factory) 1.0kW(max.)
GAS SUPPLY
LP gas or natural gas (Max. pressure<9.8kPa)


Thông tin chi tiết, xin liên hệ hệ:


Lâm Thị Thúy An

Tel: 0918 844 870

Email: [email protected]

-------------------------

Hoa Y Co., Ltd
406/63 Cong Hoa Str., Ward 13, Tan Binh Dist., HCM City
Tel: 0918 844 870

Fax: ( 848) 3812 3085

Email : [email protected]

LIÊN HỆ NHÀ CUNG CẤP

Công Ty TNHH Hoa Ý
ACO-8/8as Automated Cleveland Open Cup Flash Point Tester

    Cảm ơn Quý khách đã quan tâm đến sản phẩm trên.
    Hiện tại tài khoản doanh nghiệp đăng sản phẩm trên chưa được xác thực.
    Để mua sản phẩm, Quý khách vui lòng liên hệ chi tiết theo địa chỉ: 406/63 Cộng Hòa, P 13, Tân Bình, HCM, hoặc Email: [email protected]
    Trân trọng.

X

Người mua

Người bán

Công Ty TNHH Hoa Ý
Doanh Nghiệp Tiêu Chuẩn

Thông tin sản phẩm

Nội dung liên hệ

x
Đóng
CÔNG TY CP ĐẦU TƯ AMAKI
Địa chỉ: Toà nhà N7, số 3 đường 3/2, phường 11, Quận 10, Tp. HCM
(Trong khuôn viên Tổng Công Ty Thái Sơn - Bộ Quốc Phòng)
Điện thoại: 02862.761612 - 02862.757416 - 090 315 0099
Email: [email protected]
bộ công thương

ACO-8/8as Automated Cleveland Open Cup Flash Point Tester

ACO-8/8as Automated Cleveland Open Cup Flash Point Tester