x
THÔNG BÁO
x
ĐĂNG NHẬP
x
ĐĂNG KÝ
1
Xác thực
2
Thông tin
3
Hoàn tất
Email
Mã bảo vệ
541205
Tiếp tục
x
x
Quên mật khẩu
Hủy
x
ACTIVE VIP

Vui lòng chọn gói VIP mong muốn

Gói 6 Tháng

350,000đ

Chọn

Gói 1 Năm

800,000đ

Chọn

Gói 2 Năm

1,000,000đ

Chọn
Hủy

F325_Unipulse Vietnam_STC Vietnam liên hệ

(cập nhật 20-07-2015)
F325_Unipulse Vietnam_STC Vietnam

Liên hệ người bán

    Công ty TNHH TMDV Song Thành Công

    Điện thoại:

    Email:

    Địa chỉ:

F325_Unipulse Vietnam_STC Vietnam liên hệ

(cập nhật 20-07-2015)

    Phạm vi:

  • Tất cả chủ đề sản phẩm

    Cập nhật:

  • 20-07-2015

    ID:

  • 82242

    Xem:

  • 178
Chia sẽ qua twitter bài: F325_Unipulse Vietnam_STC VietnamF325_Unipulse Vietnam_STC VietnamF325_Unipulse Vietnam_STC Vietnam

thu.png

F325

Digital indicator with fast peak hold function

Product outline

Ideal for measuring dynamic force in short cycle

F325 is a digital indicator for strain gage type sensors (DIN 96x48mm size).

With analogue/digital hold function and high-speed signal processing capability (3000 times/sec), it enables accurate measurements of pressure, force, torque, and other dynamic factors.

It is equipped with serial interface (RS-485 or SI/F) , and up to 32 units of F325 can be connected on the same network (only with RS-485).

It is ideal for applications with short cycle time, such as tablet press or plugging machines.

※D/A converter corresponds to voltage output and current output.
※BCD output corresponds to sink type and source type.

Features

Analogue peak hold

The peak of analogue signal is captured by the peak hold circuit.

Since it is independent of sampling speed, it can hold the peak value at faster speed.

F325 analogue peak hold

Digital peak/sample hold

The peak or a sample point of digitized measurement data is captured.

It is ideal for applications where the stability of reading is required.

Hi-speed A/D conversion rate of 3000 times/sec(resolution: 24 bit)

Analogue signal from a sensor can be converted to digital signal at the rate of 3000 times/sec*.

*A/D conversion rate can be switched to 30 or 300 times/sec.

Then the effect of filter is enhanced, which, in turn, enables stable measurements.

The high-performance filtering functions by using both analogue and digital technology

Remove vibration and noise/external interference on input signal for "fast" and "accurate" reading.

Both analogue and digital filters (low-pass and moving average filter) can be used simultaneously.

Depending on requirements for applications (e.g. fast response, stable reading, etc.), you can select the optimal filter from wide range of selection.

Interface

You could chose either RS-485 ( Modbus-RTU /UNI-format) or SI/F(Unipulse original serial interface) as a standard interface.

F325Modbus

Cover wide range of applications: fast response time and high accuracy

<Fast response>

F325 processes the analogue peak hold value at the speed of 3000 times /sec. and ouputs HI/OK/LO signal.

It is ideal for the application with short cycle time.

F325 fast response


<High-accuracy>

It can be also used for highly accurate weighing system by adjusting A/D conversion speed and/or filter setting.

F325 high-accuracy

Free software for parameter setting is available

F325 can be connected to PC via RS-485 or RS-232C, and parameter setting can be edited or saved on PC.

Specifications

ANALOG SECTIONDISPLAY SECTIONEXTERNAL INPUT/OUTPUT SIGNALINTERFACEGENERAL SPECIFICATIONSAccessories

Excitation voltage

Signal input range

Equiv. input cal. range

Equiv. input cal. error

Zero・Gain adjustment

Minimum input sensitivity

Accuracy

A/D converter

Analog filter

Digital filter

Resolution

Monitor output

Hold function

ANALOG SECTION

DC10V or 2.5V±10%(switchable)

Output current: within 30mA

-3.0~+3.0mV/V

+0.5~+3.0mV/V

within 0.1%/FS(at 0.5mV/V input)

Automatic adjustment by digital processing

1μV/count

1/10000 guaranteed at 1mV/V input

(at excitation voltage:10V)

  • Non-linearity
  • :0.02%/FS±1digit (at 3mV/V input)
  • Zero drift
  • :within 0.5μV/℃ RTI
  • Gain drift
  • :within 25ppm/℃
  • Speed
  • :30, 300, 3000 times/sec(selectable)
  • Resolution
  • :24bit(binary)

Primary low-pass filter

select frequency from 10, 30, 100, 300, 1k, 3k, 10k or 30kHz

Filter1:Bessel low-pass filter(secondary)

Cut-off frequency can be set to any value from 1/300 to 1/10 of sampling speed. It can be turned off.

3000times/sec:10~300Hz, 300times/sec:1.0~30.0Hz, 30times/sec:0.1~3.00Hz

Filter2:Moving average

You can set the value anywhere between 1 to 999 times.

1/30000(at 3.0mV/V input)

Sensor input of approx. 2V per 1mV/V(Input resistance over 2kΩ)

Sample or peak hold(You can chose either analogue or digital peak hold from setting menu. Frequency response of analogue hold is 1kHz)

Display unit

Display items

DISPLAY SECTION

15mm character height:7-segment green LED(5-digits)

  • Numerical value
  • :5-digits Indicated value:-19999~+99999
  • Decimal points
  • :Selectable decimal point displaying position
    (0.000, 0.00, 0.0, 0)
  • Status display
  • :red 3φLED:HI, LO, PEAK, HOLD  green 3φLED:OK
  • Display frequency
  • :selectable from 3, 6, 13 and 25 times/sec

External input

(3)

External output

(5)

EXTERNAL INPUT/OUTPUT SIGNAL

DZ、HOLD、H.RESET

<Volt-free contact input>

External devices can be connected, such as relays, switches, transistors and so on. The signal can be outputted by making short-circuit between input and common terminal.

In case transistor is connected, please use NPN (sink) transistor .

Internal power supply voltage:DC12V, When short-circuited:Approx. 4mA

<DC-Input for both plus common and minus common type>(please specify the type of input when ordering)

External devices can be connected, such as relays, switches, transistors and so on. Input signal is outputted by applying voltage between input and common terminal.

In case a transistor is connected, please use NPN type for plus common and PNP type for minus common.

Maximum Rated Voltage: DC27.6V, "ON": when the voltage is above DC 9V (Load Current: approx. 10mA at DC24V), "OFF: " below DC3V.

HI, OK, LO, Output Selection 1, Output Selection 2

(Assign output from various selection: HH, LL, Overload, RUN, HOLD, NZ, DZ response)

PhotoMOS relay output(common for sink and source type)

Maximum rated voltage: DC30V, maximum rated current: 100mA, operating time : approx. 1 msec

INTERFACE

RS-485 communication interface (Modbus-RTU /UNI-format)or SI/F(Unipulse original serial interface)

BCD parallel data output interface(sink type)(Option)

BCD parallel data output interface(source type)(Option)

D/A converter(voltage output)(Option)

D/A converter(current output)(Option)

RS-232C communication interface(Option)

Power supply voltage

Power consumption

Rush current(Typ) AC spec.

Rush current(Typ) DC spec.

Operation condition

External dimensions

Panel cutout size

Weight

GENERAL SPECIFICATIONS

AC100V~240V(+10%-15%)(free power supply)50/60Hz

DC12V~24V(±15%)(please specify the type of input when ordering)

10W max

2A, 1msec:AC100V average load condition

(cold start at room temperature)

4A, 1msec:AC200V average load condition

(cold start at room temperature)

2A, 20msec:DC12V average load condition

(cold start at room temperature)

1A, 50msec:DC24V average load condition

(cold start at room temperature)

Operation temperature range:-10~+40℃ Storage temperature range:-40~+80℃

Humidity:85%RH or less(non-condensing)

96(W)×48(H)×132.5(D)(mm) (not including projections)

92×45(+1-0) (mm)

Approx. 600g

Accessories

・AC input cord* 1

・3P-2P conversion adapter* 1

・Terminator (RS-485 is selected) 1

・BCD output connector (BCD output option is selected) 1

・F325 operation ,amial 1

* Included only for AC specifications

Option

BCO

BSC

DAV

DAI

232

Model

Description

BCD parallel data output interface(sink type)

BCD parallel data output interface(source type)

D/A converter(voltage output)

D/A converter(current output)

RS-232C communication interface

Download

Product Catalogue

Operation manual

External dimention

Support tools

Software

GC2014

F325Rev.1.01(3.04MB)






CÔNG TY CP ĐẦU TƯ AMAKI
Địa chỉ: Toà nhà N7, số 3 đường 3/2, phường 11, Quận 10, Tp. HCM
(Trong khuôn viên Tổng Công Ty Thái Sơn - Bộ Quốc Phòng)
Điện thoại: 02862.761612 - 02862.757416 - 090 315 0099
Email: [email protected]
bộ công thương

F325_Unipulse Vietnam_STC Vietnam

F325_Unipulse Vietnam_STC Vietnam